Solis S5 Eh1P4.6K Hybrid Modbus Register 33261: Meter Active Power L3
Technical documentation for Modbus register 33261 on Solis S5 Eh1P4.6K Hybrid. Data type: S DWORD. Includes Python and YAML configuration examples.
January 16, 2026
•
3 read
Technical Definition
The register Meter Active Power L3 at address 33261 is used to monitor meter active power l3 on the Solis S5 Eh1P4.6K Hybrid.
- Protocol: Modbus RTU
- Data Type: S DWORD
- Unit: W
- Access: Read Only
How to Read (Python pymodbus)
Use this code snippet to read this specific value via RS485:
from pymodbus.client.sync import ModbusSerialClient
client = ModbusSerialClient(method='rtu', port='/dev/ttyUSB0', baudrate=9600)
client.connect()
# Read Meter Active Power L3 (Address: 33261)
# Note: Check if your device uses 0-based or 1-based addressing
result = client.read_input_registers(address=33261, count=2, unit=1)
if not result.isError():
print(f"Raw Value: {result.registers}")
else:
print("Error reading register")
client.close()
Integration (Home Assistant)
Paste this into your configuration.yaml:
- platform: modbus_controller
name: "Meter Active Power L3"
address: 33261
value_type: S_DWORD
unit_of_measurement: "W"
Connection Diagram
Here is the standard RS485 wiring for this configuration:
graph TD
PLC[Host Controller / Home Assistant]
Device[Solis S5 Eh1P4.6K Hybrid]
PLC -- "A+ (D+)" --> Device
PLC -- "B- (D-)" --> Device
PLC -- GND --> Device
💡 Engineer's Insight
Analysis: Meter Active Power L3. Unit: Watts (W). Real power consumed/produced on Phase 3.
Troubleshooting: Zero indicates no active power on L3. Check loads, generation, and connections.