Solis S5 Eh1P4.6K Hybrid Modbus Register 33253: Meter Voltage L2

Technical documentation for Modbus register 33253 on Solis S5 Eh1P4.6K Hybrid. Data type: U WORD. Includes Python and YAML configuration examples.

January 16, 2026 3 read

Technical Definition

The register Meter Voltage L2 at address 33253 is used to monitor meter voltage l2 on the Solis S5 Eh1P4.6K Hybrid.

  • Protocol: Modbus RTU
  • Data Type: U WORD
  • Unit: V
  • Access: Read Only

How to Read (Python pymodbus)

Use this code snippet to read this specific value via RS485:

from pymodbus.client.sync import ModbusSerialClient

client = ModbusSerialClient(method='rtu', port='/dev/ttyUSB0', baudrate=9600)
client.connect()

# Read Meter Voltage L2 (Address: 33253)
# Note: Check if your device uses 0-based or 1-based addressing
result = client.read_input_registers(address=33253, count=2, unit=1)

if not result.isError():
    print(f"Raw Value: {result.registers}")
else:
    print("Error reading register")

client.close()

Integration (Home Assistant)

Paste this into your configuration.yaml:

- platform: modbus_controller
  name: "Meter Voltage L2"
  address: 33253
  value_type: U_WORD
  unit_of_measurement: "V"

Connection Diagram

Here is the standard RS485 wiring for this configuration:

graph TD
    PLC[Host Controller / Home Assistant]
    Device[Solis S5 Eh1P4.6K Hybrid]

    PLC -- "A+ (D+)" --> Device
    PLC -- "B- (D-)" --> Device
    PLC -- GND --> Device


💡 Engineer's Insight

Analysis: Measures the AC voltage on Line 2 (L2) of the grid connection, typically in Volts (V).

Troubleshooting: Zero value implies no voltage or a measurement fault. Inspect grid connection and power source.