Solis Modbus Inv Addon Acr10R 1Ph Modbus Register 3264: Meter Reactive Power
Technical documentation for Modbus register 3264 on Solis Modbus Inv Addon Acr10R 1Ph. Data type: S DWORD. Includes Python and YAML configuration examples.
Technical Definition
The register Meter Reactive Power at address 3264 is used to monitor meter reactive power on the Solis Modbus Inv Addon Acr10R 1Ph.
- Protocol: Modbus RTU
- Data Type: S DWORD
- Unit: VAr
- Access: Read Only
How to Read (Python pymodbus)
Use this code snippet to read this specific value via RS485:
from pymodbus.client.sync import ModbusSerialClient
client = ModbusSerialClient(method='rtu', port='/dev/ttyUSB0', baudrate=9600)
client.connect()
# Read Meter Reactive Power (Address: 3264)
# Note: Check if your device uses 0-based or 1-based addressing
result = client.read_input_registers(address=3264, count=2, unit=1)
if not result.isError():
print(f"Raw Value: {result.registers}")
else:
print("Error reading register")
client.close()
Integration (Home Assistant)
Paste this into your configuration.yaml:
- platform: modbus_controller
name: "Meter Reactive Power"
address: 3264
value_type: S_DWORD
unit_of_measurement: "VAr"
Connection Diagram
Here is the standard RS485 wiring for this configuration:
graph TD
PLC[Host Controller / Home Assistant]
Device[Solis Modbus Inv Addon Acr10R 1Ph]
PLC -- "A+ (D+)" --> Device
PLC -- "B- (D-)" --> Device
PLC -- GND --> Device
💡 Engineer's Insight
Analysis: Measures the reactive power, typically in Volt-Amperes Reactive (VAR). Indicates energy exchanged but not converted to work.
Troubleshooting: An unexpected zero or high value might suggest power factor issues or a problem with inductive/capacitive loads. Check system configuration.