Rdtech Controller Modbus Register 34: Temperature external
Technical documentation for Modbus register 34 on Rdtech Controller. Data type: S DWORD. Includes Python and YAML configuration examples.
January 16, 2026
•
3 read
Technical Definition
The register Temperature external at address 34 is used to monitor Temperature external on the Rdtech Controller.
- Protocol: Modbus RTU
- Data Type: S DWORD
- Unit: °C
- Access: Read Only
How to Read (Python pymodbus)
Use this code snippet to read this specific value via RS485:
from pymodbus.client.sync import ModbusSerialClient
client = ModbusSerialClient(method='rtu', port='/dev/ttyUSB0', baudrate=9600)
client.connect()
# Read Temperature external (Address: 34)
# Note: Check if your device uses 0-based or 1-based addressing
result = client.read_input_registers(address=34, count=2, unit=1)
if not result.isError():
print(f"Raw Value: {result.registers}")
else:
print("Error reading register")
client.close()
Integration (Home Assistant)
Paste this into your configuration.yaml:
- platform: modbus_controller
name: "Temperature external"
address: 34
value_type: S_DWORD
unit_of_measurement: "°C"
Connection Diagram
Here is the standard RS485 wiring for this configuration:
graph TD
PLC[Host Controller / Home Assistant]
Device[Rdtech Controller]
PLC -- "A+ (D+)" --> Device
PLC -- "B- (D-)" --> Device
PLC -- GND --> Device
💡 Engineer's Insight
Analysis: External Temperature in Degrees Celsius (°C). Measures the ambient Temperature surrounding the device or a connected sensor.
Troubleshooting: Verify sensor placement and integrity. Inaccurate readings may point to sensor failure or environmental interference.