Modbus Goodwe Modbus Register 563: Feeding Power

Technical documentation for Modbus register 563 on Modbus Goodwe. Data type: U WORD. Includes Python and YAML configuration examples.

January 16, 2026 3 read

Technical Definition

The register Feeding Power at address 563 is used to monitor feeding power on the Modbus Goodwe.

  • Protocol: Modbus RTU
  • Data Type: U WORD
  • Unit: W
  • Access: Read Only

How to Read (Python pymodbus)

Use this code snippet to read this specific value via RS485:

from pymodbus.client.sync import ModbusSerialClient

client = ModbusSerialClient(method='rtu', port='/dev/ttyUSB0', baudrate=9600)
client.connect()

# Read Feeding Power (Address: 563)
# Note: Check if your device uses 0-based or 1-based addressing
result = client.read_input_registers(address=563, count=2, unit=1)

if not result.isError():
    print(f"Raw Value: {result.registers}")
else:
    print("Error reading register")

client.close()

Integration (Home Assistant)

Paste this into your configuration.yaml:

- platform: modbus_controller
  name: "Feeding Power"
  address: 563
  value_type: U_WORD
  unit_of_measurement: "W"

Connection Diagram

Here is the standard RS485 wiring for this configuration:

graph TD
    PLC[Host Controller / Home Assistant]
    Device[Modbus Goodwe]

    PLC -- "A+ (D+)" --> Device
    PLC -- "B- (D-)" --> Device
    PLC -- GND --> Device


💡 Engineer's Insight

Analysis: Current power output of the inverter, measured in Watts (W). Indicates real-time energy generation.

Troubleshooting: Zero if no solar radiation, inverter fault, or grid outage. Check panel condition and inverter status.