M5Stack Atom Lite 315Bd0 Rs485 Modbus Register 10: PWP Compressor Running Frequency
Technical documentation for Modbus register 10 on M5Stack Atom Lite 315Bd0 Rs485. Data type: U WORD. Includes Python and YAML configuration examples.
Technical Definition
The register PWP Compressor Running Frequency at address 10 is used to monitor pwp compressor running frequency on the M5Stack Atom Lite 315Bd0 Rs485.
- Protocol: Modbus RTU
- Data Type: U WORD
- Unit: Hz
- Access: Read Only
How to Read (Python pymodbus)
Use this code snippet to read this specific value via RS485:
from pymodbus.client.sync import ModbusSerialClient
client = ModbusSerialClient(method='rtu', port='/dev/ttyUSB0', baudrate=9600)
client.connect()
# Read PWP Compressor Running Frequency (Address: 10)
# Note: Check if your device uses 0-based or 1-based addressing
result = client.read_input_registers(address=10, count=2, unit=1)
if not result.isError():
print(f"Raw Value: {result.registers}")
else:
print("Error reading register")
client.close()
Integration (Home Assistant)
Paste this into your configuration.yaml:
- platform: modbus_controller
name: "PWP Compressor Running Frequency"
address: 10
value_type: U_WORD
unit_of_measurement: "Hz"
Connection Diagram
Here is the standard RS485 wiring for this configuration:
graph TD
PLC[Host Controller / Home Assistant]
Device[M5Stack Atom Lite 315Bd0 Rs485]
PLC -- "A+ (D+)" --> Device
PLC -- "B- (D-)" --> Device
PLC -- GND --> Device
💡 Engineer's Insight
Analysis: PWP Compressor operating frequency (Hz). Indicates motor speed and load. Higher values mean higher speed.
Troubleshooting: Zero reading may indicate motor stop, VFD fault, or communication issue. Check power, VFD status, and Modbus connection.