Jkbms Modbus Modbus Register 4768: JKBMS alarms bitmask
Technical documentation for Modbus register 4768 on Jkbms Modbus. Data type: U DWORD. Includes Python and YAML configuration examples.
January 16, 2026
•
1 min read
Technical Definition
The register JKBMS alarms bitmask at address 4768 is used to monitor jkbms alarms bitmask on the Jkbms Modbus.
- Protocol: Modbus RTU
- Data Type: U DWORD
- Unit:
- Access: Read Only
How to Read (Python pymodbus)
Use this code snippet to read this specific value via RS485:
from pymodbus.client.sync import ModbusSerialClient
client = ModbusSerialClient(method='rtu', port='/dev/ttyUSB0', baudrate=9600)
client.connect()
# Read JKBMS alarms bitmask (Address: 4768)
# Note: Check if your device uses 0-based or 1-based addressing
result = client.read_input_registers(address=4768, count=2, unit=1)
if not result.isError():
print(f"Raw Value: {result.registers}")
else:
print("Error reading register")
client.close()
Integration (Home Assistant)
Paste this into your configuration.yaml:
- platform: modbus_controller
name: "JKBMS alarms bitmask"
address: 4768
value_type: U_DWORD
unit_of_measurement: ""
Connection Diagram
Here is the standard RS485 wiring for this configuration:
graph TD
PLC[Host Controller / Home Assistant]
Device[Jkbms Modbus]
PLC -- "A+ (D+)" --> Device
PLC -- "B- (D-)" --> Device
PLC -- GND --> Device
💡 Engineer's Insight
Analysis: Bitmask indicating active alarm conditions. Each bit represents a specific fault (e.g., overvoltage, undervoltage, temp).
Troubleshooting: A value of zero indicates no active alarms. Non-zero requires decoding the bitmask to identify specific faults.