Inverter Modbus Register 4541: Max Total Charging Current
Technical documentation for Modbus register 4541 on Inverter. Data type: U WORD. Includes Python and YAML configuration examples.
January 16, 2026
•
1 min read
Technical Definition
The register Max Total Charging Current at address 4541 is used to monitor max total charging current on the Inverter.
- Protocol: Modbus RTU
- Data Type: U WORD
- Unit: A
- Access: Read Only
How to Read (Python pymodbus)
Use this code snippet to read this specific value via RS485:
from pymodbus.client.sync import ModbusSerialClient
client = ModbusSerialClient(method='rtu', port='/dev/ttyUSB0', baudrate=9600)
client.connect()
# Read Max Total Charging Current (Address: 4541)
# Note: Check if your device uses 0-based or 1-based addressing
result = client.read_input_registers(address=4541, count=2, unit=1)
if not result.isError():
print(f"Raw Value: {result.registers}")
else:
print("Error reading register")
client.close()
Integration (Home Assistant)
Paste this into your configuration.yaml:
- platform: modbus_controller
name: "Max Total Charging Current"
address: 4541
value_type: U_WORD
unit_of_measurement: "A"
Connection Diagram
Here is the standard RS485 wiring for this configuration:
graph TD
PLC[Host Controller / Home Assistant]
Device[Inverter]
PLC -- "A+ (D+)" --> Device
PLC -- "B- (D-)" --> Device
PLC -- GND --> Device
💡 Engineer's Insight
Analysis: Specifies the maximum permissible total charging current to the battery in Amperes (A). Protects battery from overcurrent.
Troubleshooting: Unexpected zero might indicate charger disabled, battery issue, or control system malfunction.