Inverter Info Modbus Register 4527: Nominal output frequency

Technical documentation for Modbus register 4527 on Inverter Info. Data type: U WORD. Includes Python and YAML configuration examples.

January 16, 2026 3 read

Technical Definition

The register Nominal output frequency at address 4527 is used to monitor nominal output frequency on the Inverter Info.

  • Protocol: Modbus RTU
  • Data Type: U WORD
  • Unit: Hz
  • Access: Read Only

How to Read (Python pymodbus)

Use this code snippet to read this specific value via RS485:

from pymodbus.client.sync import ModbusSerialClient

client = ModbusSerialClient(method='rtu', port='/dev/ttyUSB0', baudrate=9600)
client.connect()

# Read Nominal output frequency (Address: 4527)
# Note: Check if your device uses 0-based or 1-based addressing
result = client.read_input_registers(address=4527, count=2, unit=1)

if not result.isError():
    print(f"Raw Value: {result.registers}")
else:
    print("Error reading register")

client.close()

Integration (Home Assistant)

Paste this into your configuration.yaml:

- platform: modbus_controller
  name: "Nominal output frequency"
  address: 4527
  value_type: U_WORD
  unit_of_measurement: "Hz"

Connection Diagram

Here is the standard RS485 wiring for this configuration:

graph TD
    PLC[Host Controller / Home Assistant]
    Device[Inverter Info]

    PLC -- "A+ (D+)" --> Device
    PLC -- "B- (D-)" --> Device
    PLC -- GND --> Device


💡 Engineer's Insight

Analysis: Nominal output AC frequency (Hz) the inverter is designed to produce. Critical for grid connection and appliance operation.

Troubleshooting: Zero frequency indicates the inverter is not operating or is in a fault condition, preventing power output.