Huawei Inverter Modbus Register 32072: Grid Current

Technical documentation for Modbus register 32072 on Huawei Inverter. Data type: S DWORD. Includes Python and YAML configuration examples.

January 16, 2026 1 min read

Technical Definition

The register Grid Current at address 32072 is used to monitor grid current on the Huawei Inverter.

  • Protocol: Modbus RTU
  • Data Type: S DWORD
  • Unit: A
  • Access: Read Only

How to Read (Python pymodbus)

Use this code snippet to read this specific value via RS485:

from pymodbus.client.sync import ModbusSerialClient

client = ModbusSerialClient(method='rtu', port='/dev/ttyUSB0', baudrate=9600)
client.connect()

# Read Grid Current (Address: 32072)
# Note: Check if your device uses 0-based or 1-based addressing
result = client.read_input_registers(address=32072, count=2, unit=1)

if not result.isError():
    print(f"Raw Value: {result.registers}")
else:
    print("Error reading register")

client.close()

Integration (Home Assistant)

Paste this into your configuration.yaml:

- platform: modbus_controller
  name: "Grid Current"
  address: 32072
  value_type: S_DWORD
  unit_of_measurement: "A"

Connection Diagram

Here is the standard RS485 wiring for this configuration:

graph TD
    PLC[Host Controller / Home Assistant]
    Device[Huawei Inverter]

    PLC -- "A+ (D+)" --> Device
    PLC -- "B- (D-)" --> Device
    PLC -- GND --> Device


💡 Engineer's Insight

Analysis: Current flowing from the inverter to the grid (Amperes).

Troubleshooting: Zero may signify no power generation, grid disconnect, or inverter underperformance.