Heidelberg Wb Modbus Register 8: L3 A rms
Technical documentation for Modbus register 8 on Heidelberg Wb. Data type: U WORD. Includes Python and YAML configuration examples.
January 16, 2026
•
1 min read
Technical Definition
The register L3 A rms at address 8 is used to monitor l3 a rms on the Heidelberg Wb.
- Protocol: Modbus RTU
- Data Type: U WORD
- Unit: A rms
- Access: Read Only
How to Read (Python pymodbus)
Use this code snippet to read this specific value via RS485:
from pymodbus.client.sync import ModbusSerialClient
client = ModbusSerialClient(method='rtu', port='/dev/ttyUSB0', baudrate=9600)
client.connect()
# Read L3 A rms (Address: 8)
# Note: Check if your device uses 0-based or 1-based addressing
result = client.read_input_registers(address=8, count=2, unit=1)
if not result.isError():
print(f"Raw Value: {result.registers}")
else:
print("Error reading register")
client.close()
Integration (Home Assistant)
Paste this into your configuration.yaml:
- platform: modbus_controller
name: "L3 A rms"
address: 8
value_type: U_WORD
unit_of_measurement: "A rms"
Connection Diagram
Here is the standard RS485 wiring for this configuration:
graph TD
PLC[Host Controller / Home Assistant]
Device[Heidelberg Wb]
PLC -- "A+ (D+)" --> Device
PLC -- "B- (D-)" --> Device
PLC -- GND --> Device
💡 Engineer's Insight
Analysis: RMS value of Line 3 current. Units: Amperes (A). Indicates electrical load on L3.
Troubleshooting: Zero reading may indicate no load, open circuit on L3, or a sensor fault.