Heatpump Modbus Register 162: Total heating power consumed for master unit
Technical documentation for Modbus register 162 on heatpump. Data type: U DWORD. Includes Python and YAML configuration examples.
January 16, 2026
•
3 read
Technical Definition
The register Total heating power consumed for master unit at address 162 is used to monitor total heating power consumed for master unit on the heatpump.
- Protocol: Modbus RTU
- Data Type: U DWORD
- Unit: kWh
- Access: Read Only
How to Read (Python pymodbus)
Use this code snippet to read this specific value via RS485:
from pymodbus.client.sync import ModbusSerialClient
client = ModbusSerialClient(method='rtu', port='/dev/ttyUSB0', baudrate=9600)
client.connect()
# Read Total heating power consumed for master unit (Address: 162)
# Note: Check if your device uses 0-based or 1-based addressing
result = client.read_input_registers(address=162, count=2, unit=1)
if not result.isError():
print(f"Raw Value: {result.registers}")
else:
print("Error reading register")
client.close()
Integration (Home Assistant)
Paste this into your configuration.yaml:
- platform: modbus_controller
name: "Total heating power consumed for master unit"
address: 162
value_type: U_DWORD
unit_of_measurement: "kWh"
Connection Diagram
Here is the standard RS485 wiring for this configuration:
graph TD
PLC[Host Controller / Home Assistant]
Device[heatpump]
PLC -- "A+ (D+)" --> Device
PLC -- "B- (D-)" --> Device
PLC -- GND --> Device
💡 Engineer's Insight
Analysis: Total cumulative heating power consumed in kWh for the master unit since reset.
Troubleshooting: Zero if the master unit is not consuming power for heating. Verify operation and sensor readings.