Heatpump Modbus Register 132: Entity prefix Compressor Target Frequency

Technical documentation for Modbus register 132 on heatpump. Data type: U WORD. Includes Python and YAML configuration examples.

January 16, 2026 3 read

Technical Definition

The register entity prefix Compressor Target Frequency at address 132 is used to monitor entity prefix compressor target frequency on the heatpump.

  • Protocol: Modbus RTU
  • Data Type: U WORD
  • Unit: Hz
  • Access: Read Only

How to Read (Python pymodbus)

Use this code snippet to read this specific value via RS485:

from pymodbus.client.sync import ModbusSerialClient

client = ModbusSerialClient(method='rtu', port='/dev/ttyUSB0', baudrate=9600)
client.connect()

# Read entity_prefix Compressor Target Frequency (Address: 132)
# Note: Check if your device uses 0-based or 1-based addressing
result = client.read_input_registers(address=132, count=2, unit=1)

if not result.isError():
    print(f"Raw Value: {result.registers}")
else:
    print("Error reading register")

client.close()

Integration (Home Assistant)

Paste this into your configuration.yaml:

- platform: modbus_controller
  name: "entity_prefix Compressor Target Frequency"
  address: 132
  value_type: U_WORD
  unit_of_measurement: "Hz"

Connection Diagram

Here is the standard RS485 wiring for this configuration:

graph TD
    PLC[Host Controller / Home Assistant]
    Device[heatpump]

    PLC -- "A+ (D+)" --> Device
    PLC -- "B- (D-)" --> Device
    PLC -- GND --> Device


💡 Engineer's Insight

Analysis: Indicates the target operating frequency (Hz) for the compressor. Reflects demand and performance control.

Troubleshooting: Zero frequency means the compressor is stopped. Could be normal idle, demand absence, or due to a protective shutdown/fault.