Felicity Speicher Modbus Register 4871: Bat2 Current

Technical documentation for Modbus register 4871 on Felicity Speicher. Data type: S WORD. Includes Python and YAML configuration examples.

January 16, 2026 1 min read

Technical Definition

The register Bat2 Current at address 4871 is used to monitor bat2 current on the Felicity Speicher.

  • Protocol: Modbus RTU
  • Data Type: S WORD
  • Unit: A
  • Access: Read Only

How to Read (Python pymodbus)

Use this code snippet to read this specific value via RS485:

from pymodbus.client.sync import ModbusSerialClient

client = ModbusSerialClient(method='rtu', port='/dev/ttyUSB0', baudrate=9600)
client.connect()

# Read Bat2 Current (Address: 4871)
# Note: Check if your device uses 0-based or 1-based addressing
result = client.read_input_registers(address=4871, count=2, unit=1)

if not result.isError():
    print(f"Raw Value: {result.registers}")
else:
    print("Error reading register")

client.close()

Integration (Home Assistant)

Paste this into your configuration.yaml:

- platform: modbus_controller
  name: "Bat2 Current"
  address: 4871
  value_type: S_WORD
  unit_of_measurement: "A"

Connection Diagram

Here is the standard RS485 wiring for this configuration:

graph TD
    PLC[Host Controller / Home Assistant]
    Device[Felicity Speicher]

    PLC -- "A+ (D+)" --> Device
    PLC -- "B- (D-)" --> Device
    PLC -- GND --> Device


💡 Engineer's Insight

Analysis: Current of Battery 2 in Amperes (A). Shows charge/discharge rate.

Troubleshooting: Zero value means no current flow, possibly due to battery idle, protection trip, or fault.