Ev Charge Modbus Register 6: EVPower

Technical documentation for Modbus register 6 on Ev Charge. Data type: U WORD. Includes Python and YAML configuration examples.

January 16, 2026 1 min read

Technical Definition

The register EVPower at address 6 is used to monitor evpower on the Ev Charge.

  • Protocol: Modbus RTU
  • Data Type: U WORD
  • Unit: W
  • Access: Read Only

How to Read (Python pymodbus)

Use this code snippet to read this specific value via RS485:

from pymodbus.client.sync import ModbusSerialClient

client = ModbusSerialClient(method='rtu', port='/dev/ttyUSB0', baudrate=9600)
client.connect()

# Read EVPower (Address: 6)
# Note: Check if your device uses 0-based or 1-based addressing
result = client.read_input_registers(address=6, count=2, unit=1)

if not result.isError():
    print(f"Raw Value: {result.registers}")
else:
    print("Error reading register")

client.close()

Integration (Home Assistant)

Paste this into your configuration.yaml:

- platform: modbus_controller
  name: "EVPower"
  address: 6
  value_type: U_WORD
  unit_of_measurement: "W"

Connection Diagram

Here is the standard RS485 wiring for this configuration:

graph TD
    PLC[Host Controller / Home Assistant]
    Device[Ev Charge]

    PLC -- "A+ (D+)" --> Device
    PLC -- "B- (D-)" --> Device
    PLC -- GND --> Device


💡 Engineer's Insight

Analysis: Instantaneous power being drawn by the EV (e.g., kW).

Troubleshooting: Low vehicle demand, charger fault, or communication issue with EV.