EmsTechLabs Logo EmsTechLabs

Esphome Shoto Smartli Modbus Register 44: Vcell11

Technical documentation for Modbus register 44 on Esphome Shoto Smartli. Data type: U WORD. Includes Python and YAML configuration examples.

January 16, 2026 3 read

Technical Definition

The register Vcell11 at address 44 is used to monitor vcell11 on the Esphome Shoto Smartli.

  • Protocol: Modbus RTU
  • Data Type: U WORD
  • Unit: V
  • Access: Read Only

How to Read (Python pymodbus)

Use this code snippet to read this specific value via RS485:

from pymodbus.client.sync import ModbusSerialClient

client = ModbusSerialClient(method='rtu', port='/dev/ttyUSB0', baudrate=9600)
client.connect()

# Read Vcell11 (Address: 44)
# Note: Check if your device uses 0-based or 1-based addressing
result = client.read_input_registers(address=44, count=2, unit=1)

if not result.isError():
    print(f"Raw Value: {result.registers}")
else:
    print("Error reading register")

client.close()

Integration (Home Assistant)

Paste this into your configuration.yaml:

- platform: modbus_controller
  name: "Vcell11"
  address: 44
  value_type: U_WORD
  unit_of_measurement: "V"

Connection Diagram

Here is the standard RS485 wiring for this configuration:

graph TD
    PLC[Host Controller / Home Assistant]
    Device[Esphome Shoto Smartli]

    PLC -- "A+ (D+)" --> Device
    PLC -- "B- (D-)" --> Device
    PLC -- GND --> Device


💡 Engineer's Insight

Analysis: Voltage of cell 11 in Volts (V). Key parameter for battery pack balance.

Troubleshooting: 0 might signal a damaged cell, open circuit, or communication issue. Verify cell status and wiring.