Esp32 Epever 4210An Modbus Register 12571: Remote battery Temperature
Technical documentation for Modbus register 12571 on Esp32 Epever 4210An. Data type: S WORD. Includes Python and YAML configuration examples.
January 16, 2026
•
1 min read
Technical Definition
The register Remote battery Temperature at address 12571 is used to monitor remote battery Temperature on the Esp32 Epever 4210An.
- Protocol: Modbus RTU
- Data Type: S WORD
- Unit: °C
- Access: Read Only
How to Read (Python pymodbus)
Use this code snippet to read this specific value via RS485:
from pymodbus.client.sync import ModbusSerialClient
client = ModbusSerialClient(method='rtu', port='/dev/ttyUSB0', baudrate=9600)
client.connect()
# Read Remote battery temperature (Address: 12571)
# Note: Check if your device uses 0-based or 1-based addressing
result = client.read_input_registers(address=12571, count=2, unit=1)
if not result.isError():
print(f"Raw Value: {result.registers}")
else:
print("Error reading register")
client.close()
Integration (Home Assistant)
Paste this into your configuration.yaml:
- platform: modbus_controller
name: "Remote battery temperature"
address: 12571
value_type: S_WORD
unit_of_measurement: "°C"
Connection Diagram
Here is the standard RS485 wiring for this configuration:
graph TD
PLC[Host Controller / Home Assistant]
Device[Esp32 Epever 4210An]
PLC -- "A+ (D+)" --> Device
PLC -- "B- (D-)" --> Device
PLC -- GND --> Device
💡 Engineer's Insight
Analysis: Measures remote battery Temperature. Units: Degrees Celsius (°C). Essential for optimal charging and battery health monitoring.
Troubleshooting: Sensor disconnection, faulty sensor, or communication error between the Epever controller and the remote sensor.