Technical Definition
The register Consumed energy total at address 13066 is used to monitor consumed energy total on the Esp32 C3 Zero Epever.
- Protocol: Modbus RTU
- Data Type: U DWORD R
- Unit: kWh
- Access: Read Only
How to Read (Python pymodbus)
Use this code snippet to read this specific value via RS485:
from pymodbus.client.sync import ModbusSerialClient
client = ModbusSerialClient(method='rtu', port='/dev/ttyUSB0', baudrate=9600)
client.connect()
# Read Consumed energy total (Address: 13066)
# Note: Check if your device uses 0-based or 1-based addressing
result = client.read_input_registers(address=13066, count=2, unit=1)
if not result.isError():
print(f"Raw Value: {result.registers}")
else:
print("Error reading register")
client.close()
Integration (Home Assistant)
Paste this into your configuration.yaml:
- platform: modbus_controller
name: "Consumed energy total"
address: 13066
value_type: U_DWORD_R
unit_of_measurement: "kWh"
Connection Diagram
Here is the standard RS485 wiring for this configuration:
graph TD
PLC[Host Controller / Home Assistant]
Device[Esp32 C3 Zero Epever]
PLC -- "A+ (D+)" --> Device
PLC -- "B- (D-)" --> Device
PLC -- GND --> Device
💡 Engineer's Insight
Analysis: Total consumed energy since system initialization. Units: Kilowatt-hours (kWh). Cumulative energy drawn by loads.
Troubleshooting: Zero may indicate a new system, data reset, or a persistent monitoring error. Check initialization date if available.