Epever Modbus Register 12558: Load power

Technical documentation for Modbus register 12558 on Epever. Data type: U DWORD R. Includes Python and YAML configuration examples.

January 16, 2026 1 min read

Technical Definition

The register Load power at address 12558 is used to monitor load power on the Epever.

  • Protocol: Modbus RTU
  • Data Type: U DWORD R
  • Unit: W
  • Access: Read Only

How to Read (Python pymodbus)

Use this code snippet to read this specific value via RS485:

from pymodbus.client.sync import ModbusSerialClient

client = ModbusSerialClient(method='rtu', port='/dev/ttyUSB0', baudrate=9600)
client.connect()

# Read Load power (Address: 12558)
# Note: Check if your device uses 0-based or 1-based addressing
result = client.read_input_registers(address=12558, count=2, unit=1)

if not result.isError():
    print(f"Raw Value: {result.registers}")
else:
    print("Error reading register")

client.close()

Integration (Home Assistant)

Paste this into your configuration.yaml:

- platform: modbus_controller
  name: "Load power"
  address: 12558
  value_type: U_DWORD_R
  unit_of_measurement: "W"

Connection Diagram

Here is the standard RS485 wiring for this configuration:

graph TD
    PLC[Host Controller / Home Assistant]
    Device[Epever]

    PLC -- "A+ (D+)" --> Device
    PLC -- "B- (D-)" --> Device
    PLC -- GND --> Device


💡 Engineer's Insight

Analysis: Load power consumption in Watts (W). Indicates current energy demand from the load.

Troubleshooting: Zero may indicate no load connected, load is off, or a fault within the load or charge controller.