Easun Modbus Register 211: Name output effective Current

Technical documentation for Modbus register 211 on Easun. Data type: S WORD. Includes Python and YAML configuration examples.

January 16, 2026 1 min read

Technical Definition

The register name output effective Current at address 211 is used to monitor name output effective current on the Easun.

  • Protocol: Modbus RTU
  • Data Type: S WORD
  • Unit: A
  • Access: Read Only

How to Read (Python pymodbus)

Use this code snippet to read this specific value via RS485:

from pymodbus.client.sync import ModbusSerialClient

client = ModbusSerialClient(method='rtu', port='/dev/ttyUSB0', baudrate=9600)
client.connect()

# Read name output effective Current (Address: 211)
# Note: Check if your device uses 0-based or 1-based addressing
result = client.read_input_registers(address=211, count=2, unit=1)

if not result.isError():
    print(f"Raw Value: {result.registers}")
else:
    print("Error reading register")

client.close()

Integration (Home Assistant)

Paste this into your configuration.yaml:

- platform: modbus_controller
  name: "name output effective Current"
  address: 211
  value_type: S_WORD
  unit_of_measurement: "A"

Connection Diagram

Here is the standard RS485 wiring for this configuration:

graph TD
    PLC[Host Controller / Home Assistant]
    Device[Easun]

    PLC -- "A+ (D+)" --> Device
    PLC -- "B- (D-)" --> Device
    PLC -- GND --> Device


💡 Engineer's Insight

Analysis: Measures the effective RMS current delivered to the final load. Units: Amperes (A). Reflects the actual load demand.

Troubleshooting: Zero current implies no load is connected or a break in the output circuit, possibly due to overload protection.