Deye12 Modbus Register 599: Sun12k-Grid Voltage L2
Technical documentation for Modbus register 599 on Deye12. Data type: U WORD. Includes Python and YAML configuration examples.
January 16, 2026
•
3 read
Technical Definition
The register sun12k-Grid Voltage L2 at address 599 is used to monitor sun12k-grid voltage l2 on the Deye12.
- Protocol: Modbus RTU
- Data Type: U WORD
- Unit: V
- Access: Read Only
How to Read (Python pymodbus)
Use this code snippet to read this specific value via RS485:
from pymodbus.client.sync import ModbusSerialClient
client = ModbusSerialClient(method='rtu', port='/dev/ttyUSB0', baudrate=9600)
client.connect()
# Read sun12k-Grid Voltage L2 (Address: 599)
# Note: Check if your device uses 0-based or 1-based addressing
result = client.read_input_registers(address=599, count=2, unit=1)
if not result.isError():
print(f"Raw Value: {result.registers}")
else:
print("Error reading register")
client.close()
Integration (Home Assistant)
Paste this into your configuration.yaml:
- platform: modbus_controller
name: "sun12k-Grid Voltage L2"
address: 599
value_type: U_WORD
unit_of_measurement: "V"
Connection Diagram
Here is the standard RS485 wiring for this configuration:
graph TD
PLC[Host Controller / Home Assistant]
Device[Deye12]
PLC -- "A+ (D+)" --> Device
PLC -- "B- (D-)" --> Device
PLC -- GND --> Device
💡 Engineer's Insight
Analysis: Grid Voltage L2 (V). Essential for inverter operation and grid synchronization. Typically AC RMS value.
Troubleshooting: Zero reading may indicate a tripped breaker, loose connection, or grid outage. Check fuses and grid supply.