Deye Seplosv3 Modbus Register 556: Device type-Error1
Technical documentation for Modbus register 556 on Deye Seplosv3. Data type: U WORD. Includes Python and YAML configuration examples.
January 16, 2026
•
1 min read
Technical Definition
The register device type-Error1 at address 556 is used to monitor device type-error1 on the Deye Seplosv3.
- Protocol: Modbus RTU
- Data Type: U WORD
- Unit:
- Access: Read Only
How to Read (Python pymodbus)
Use this code snippet to read this specific value via RS485:
from pymodbus.client.sync import ModbusSerialClient
client = ModbusSerialClient(method='rtu', port='/dev/ttyUSB0', baudrate=9600)
client.connect()
# Read device_type-Error1 (Address: 556)
# Note: Check if your device uses 0-based or 1-based addressing
result = client.read_input_registers(address=556, count=2, unit=1)
if not result.isError():
print(f"Raw Value: {result.registers}")
else:
print("Error reading register")
client.close()
Integration (Home Assistant)
Paste this into your configuration.yaml:
- platform: modbus_controller
name: "device_type-Error1"
address: 556
value_type: U_WORD
unit_of_measurement: ""
Connection Diagram
Here is the standard RS485 wiring for this configuration:
graph TD
PLC[Host Controller / Home Assistant]
Device[Deye Seplosv3]
PLC -- "A+ (D+)" --> Device
PLC -- "B- (D-)" --> Device
PLC -- GND --> Device
💡 Engineer's Insight
Analysis: Indicates the first active error code from the system. Consult manual for specific code meaning.
Troubleshooting: Check error code definition. Investigate related system components and parameters for the cause. System may be halted.