Device Seplosbmsv3 Modbus Register 4097: Name bms name battery current
Technical documentation for Modbus register 4097 on Device Seplosbmsv3. Data type: S WORD. Includes Python and YAML configuration examples.
January 16, 2026
•
1 min read
Technical Definition
The register name bms name battery current at address 4097 is used to monitor name bms name battery current on the Device Seplosbmsv3.
- Protocol: Modbus RTU
- Data Type: S WORD
- Unit: A
- Access: Read Only
How to Read (Python pymodbus)
Use this code snippet to read this specific value via RS485:
from pymodbus.client.sync import ModbusSerialClient
client = ModbusSerialClient(method='rtu', port='/dev/ttyUSB0', baudrate=9600)
client.connect()
# Read name_bms_name_battery_current (Address: 4097)
# Note: Check if your device uses 0-based or 1-based addressing
result = client.read_input_registers(address=4097, count=2, unit=1)
if not result.isError():
print(f"Raw Value: {result.registers}")
else:
print("Error reading register")
client.close()
Integration (Home Assistant)
Paste this into your configuration.yaml:
- platform: modbus_controller
name: "name_bms_name_battery_current"
address: 4097
value_type: S_WORD
unit_of_measurement: "A"
Connection Diagram
Here is the standard RS485 wiring for this configuration:
graph TD
PLC[Host Controller / Home Assistant]
Device[Device Seplosbmsv3]
PLC -- "A+ (D+)" --> Device
PLC -- "B- (D-)" --> Device
PLC -- GND --> Device
💡 Engineer's Insight
Analysis: Current flowing into or out of the battery pack (in Amperes). Monitors charging or discharging activity.
Troubleshooting: Zero could mean no load/charge, a break in the current path, or a faulty current sensor. Verify connections and sensor functionality.