Default Enm 223 R1 Plc Lite Modbus Register 100: Enm prefix Urms L1

Technical documentation for Modbus register 100 on Default Enm 223 R1 Plc Lite. Data type: U WORD. Includes Python and YAML configuration examples.

January 16, 2026 1 min read

Technical Definition

The register enm prefix Urms L1 at address 100 is used to monitor enm prefix urms l1 on the Default Enm 223 R1 Plc Lite.

  • Protocol: Modbus RTU
  • Data Type: U WORD
  • Unit: V
  • Access: Read Only

How to Read (Python pymodbus)

Use this code snippet to read this specific value via RS485:

from pymodbus.client.sync import ModbusSerialClient

client = ModbusSerialClient(method='rtu', port='/dev/ttyUSB0', baudrate=9600)
client.connect()

# Read enm_prefix Urms L1 (Address: 100)
# Note: Check if your device uses 0-based or 1-based addressing
result = client.read_input_registers(address=100, count=2, unit=1)

if not result.isError():
    print(f"Raw Value: {result.registers}")
else:
    print("Error reading register")

client.close()

Integration (Home Assistant)

Paste this into your configuration.yaml:

- platform: modbus_controller
  name: "enm_prefix Urms L1"
  address: 100
  value_type: U_WORD
  unit_of_measurement: "V"

Connection Diagram

Here is the standard RS485 wiring for this configuration:

graph TD
    PLC[Host Controller / Home Assistant]
    Device[Default Enm 223 R1 Plc Lite]

    PLC -- "A+ (D+)" --> Device
    PLC -- "B- (D-)" --> Device
    PLC -- GND --> Device


💡 Engineer's Insight

Analysis: RMS Voltage for Line 1 (L1) in Volts (V). Measures effective voltage value for L1.

Troubleshooting: Zero voltage indicates no power on L1, blown fuse, or wiring fault. Check circuit breaker and connections.