D1 Mini Pro Modbus Modbus Register 8: Friendly name LastValidI1

Technical documentation for Modbus register 8 on D1 Mini Pro Modbus. Data type: S WORD. Includes Python and YAML configuration examples.

January 16, 2026 1 min read

Technical Definition

The register friendly name LastValidI1 at address 8 is used to monitor friendly name lastvalidi1 on the D1 Mini Pro Modbus.

  • Protocol: Modbus RTU
  • Data Type: S WORD
  • Unit: A
  • Access: Read Only

How to Read (Python pymodbus)

Use this code snippet to read this specific value via RS485:

from pymodbus.client.sync import ModbusSerialClient

client = ModbusSerialClient(method='rtu', port='/dev/ttyUSB0', baudrate=9600)
client.connect()

# Read friendly_name LastValidI1 (Address: 8)
# Note: Check if your device uses 0-based or 1-based addressing
result = client.read_input_registers(address=8, count=2, unit=1)

if not result.isError():
    print(f"Raw Value: {result.registers}")
else:
    print("Error reading register")

client.close()

Integration (Home Assistant)

Paste this into your configuration.yaml:

- platform: modbus_controller
  name: "friendly_name LastValidI1"
  address: 8
  value_type: S_WORD
  unit_of_measurement: "A"

Connection Diagram

Here is the standard RS485 wiring for this configuration:

graph TD
    PLC[Host Controller / Home Assistant]
    Device[D1 Mini Pro Modbus]

    PLC -- "A+ (D+)" --> Device
    PLC -- "B- (D-)" --> Device
    PLC -- GND --> Device


💡 Engineer's Insight

Analysis: Last known valid value for input I1 (Current, Amps).

Troubleshooting: Zero if I1 is not connected, shorted, open, or measurement failed.