Ctc Ecozenith I250 Modbus Register 559: Heating circuit 1: Primary flow setpoint Temperature
Technical documentation for Modbus register 559 on Ctc Ecozenith I250. Data type: S WORD. Includes Python and YAML configuration examples.
Technical Definition
The register Heating circuit 1: Primary flow setpoint Temperature at address 559 is used to monitor heating circuit 1: primary flow setpoint Temperature on the Ctc Ecozenith I250.
- Protocol: Modbus RTU
- Data Type: S WORD
- Unit: °C
- Access: Read Only
How to Read (Python pymodbus)
Use this code snippet to read this specific value via RS485:
from pymodbus.client.sync import ModbusSerialClient
client = ModbusSerialClient(method='rtu', port='/dev/ttyUSB0', baudrate=9600)
client.connect()
# Read Heating circuit 1: Primary flow setpoint temperature (Address: 559)
# Note: Check if your device uses 0-based or 1-based addressing
result = client.read_input_registers(address=559, count=2, unit=1)
if not result.isError():
print(f"Raw Value: {result.registers}")
else:
print("Error reading register")
client.close()
Integration (Home Assistant)
Paste this into your configuration.yaml:
- platform: modbus_controller
name: "Heating circuit 1: Primary flow setpoint temperature"
address: 559
value_type: S_WORD
unit_of_measurement: "°C"
Connection Diagram
Here is the standard RS485 wiring for this configuration:
graph TD
PLC[Host Controller / Home Assistant]
Device[Ctc Ecozenith I250]
PLC -- "A+ (D+)" --> Device
PLC -- "B- (D-)" --> Device
PLC -- GND --> Device
💡 Engineer's Insight
Analysis: Target Temperature for the primary heating circuit flow (°C). Sets the desired water Temperature delivered to the heating system.
Troubleshooting: Zero indicates a potential control system issue or no heating requirement. Verify control logic and system demand.