Bms Sensors Pace Rs485 Bms Full Modbus Register 35: mosfet Temperature
Technical documentation for Modbus register 35 on Bms Sensors Pace Rs485 Bms Full. Data type: S WORD. Includes Python and YAML configuration examples.
January 16, 2026
•
1 min read
Technical Definition
The register mosfet Temperature at address 35 is used to monitor mosfet Temperature on the Bms Sensors Pace Rs485 Bms Full.
- Protocol: Modbus RTU
- Data Type: S WORD
- Unit: ˚C
- Access: Read Only
How to Read (Python pymodbus)
Use this code snippet to read this specific value via RS485:
from pymodbus.client.sync import ModbusSerialClient
client = ModbusSerialClient(method='rtu', port='/dev/ttyUSB0', baudrate=9600)
client.connect()
# Read mosfet temperature (Address: 35)
# Note: Check if your device uses 0-based or 1-based addressing
result = client.read_input_registers(address=35, count=2, unit=1)
if not result.isError():
print(f"Raw Value: {result.registers}")
else:
print("Error reading register")
client.close()
Integration (Home Assistant)
Paste this into your configuration.yaml:
- platform: modbus_controller
name: "mosfet temperature"
address: 35
value_type: S_WORD
unit_of_measurement: "˚C"
Connection Diagram
Here is the standard RS485 wiring for this configuration:
graph TD
PLC[Host Controller / Home Assistant]
Device[Bms Sensors Pace Rs485 Bms Full]
PLC -- "A+ (D+)" --> Device
PLC -- "B- (D-)" --> Device
PLC -- GND --> Device
💡 Engineer's Insight
Analysis: Temperature of the MOSFETs (°C). Indicates power stage thermal load.
Troubleshooting: Overheating or sensor error. Check cooling and MOSFET integrity.