Atom S3 Lite Rs485 Modbus Register 32101: Battery Current

Technical documentation for Modbus register 32101 on Atom S3 Lite Rs485. Data type: S WORD. Includes Python and YAML configuration examples.

January 16, 2026 1 min read

Technical Definition

The register Battery Current at address 32101 is used to monitor battery current on the Atom S3 Lite Rs485.

  • Protocol: Modbus RTU
  • Data Type: S WORD
  • Unit: A
  • Access: Read Only

How to Read (Python pymodbus)

Use this code snippet to read this specific value via RS485:

from pymodbus.client.sync import ModbusSerialClient

client = ModbusSerialClient(method='rtu', port='/dev/ttyUSB0', baudrate=9600)
client.connect()

# Read Battery Current (Address: 32101)
# Note: Check if your device uses 0-based or 1-based addressing
result = client.read_input_registers(address=32101, count=2, unit=1)

if not result.isError():
    print(f"Raw Value: {result.registers}")
else:
    print("Error reading register")

client.close()

Integration (Home Assistant)

Paste this into your configuration.yaml:

- platform: modbus_controller
  name: "Battery Current"
  address: 32101
  value_type: S_WORD
  unit_of_measurement: "A"

Connection Diagram

Here is the standard RS485 wiring for this configuration:

graph TD
    PLC[Host Controller / Home Assistant]
    Device[Atom S3 Lite Rs485]

    PLC -- "A+ (D+)" --> Device
    PLC -- "B- (D-)" --> Device
    PLC -- GND --> Device


💡 Engineer's Insight

Analysis: Current flowing into or out of the battery. Typically in Amperes (A). Positive for charging, negative for discharging.

Troubleshooting: 0 A means no current flow. Could be normal state, battery full/empty, or faulty current sensor/connection.